General information:
IMPORTANT: CE channels are „M” type channels according to PN-EN1433 which require an additional support in a form of a concrete apron. Channels should be installed according to CE LINEAR DRAINAGE INSTALLATION MANUAL
SYTEC drains with a protective edge
INDEX | HEIGHT [mm] | HEIGHT [mm] | WIDTH D z [mm] | WIDTH D w [mm] | LENGTH L [mm] | ACTIVE AVERAGE SECTION AREA [m2] | ||
Cast iron edging strips F900 | BEGINING H z-p | END H z-k | BEGINING H w-p | END H w-k | ||||
CE10.001 | 127 | 133 | 112 | 118 | 154 | 100 | 1000 | 0,0104 |
CE10.002 | 133 | 139 | 118 | 124 | 154 | 100 | 1000 | 0,0110 |
CE10.003 | 139 | 145 | 124 | 130 | 154 | 100 | 1000 | 0,0116 |
CE10.004 | 145 | 151 | 130 | 136 | 154 | 100 | 1000 | 0,0122 |
CE10.005* | 151 | 157 | 136 | 142 | 154 | 100 | 1000 | 0,0128 |
CE10.006 | 157 | 163 | 142 | 148 | 154 | 100 | 1000 | 0,0134 |
CE10.007 | 163 | 169 | 148 | 154 | 154 | 100 | 1000 | 0,0140 |
CE10.008 | 169 | 175 | 154 | 160 | 154 | 100 | 1000 | 0,0146 |
CE10.009 | 175 | 181 | 160 | 166 | 154 | 100 | 1000 | 0,0152 |
CE10.010* | 181 | 187 | 166 | 172 | 154 | 100 | 1000 | 0,0158 |
CE10.011 | 187 | 193 | 172 | 178 | 154 | 100 | 1000 | 0,0164 |
CE10.012 | 193 | 199 | 178 | 184 | 154 | 100 | 1000 | 0,0170 |
CE10.013 | 199 | 205 | 184 | 190 | 154 | 100 | 1000 | 0,0176 |
CE10.014 | 205 | 211 | 190 | 196 | 154 | 100 | 1000 | 0,0182 |
CE10.015* | 211 | 217 | 196 | 202 | 154 | 100 | 1000 | 0,0188 |
CE10.016 | 217 | 223 | 202 | 208 | 154 | 100 | 1000 | 0,0194 |
CE10.017 | 223 | 229 | 208 | 214 | 154 | 100 | 1000 | 0,0200 |
CE10.018 | 229 | 235 | 214 | 220 | 154 | 100 | 1000 | 0,0206 |
CE10.019 | 235 | 241 | 220 | 226 | 154 | 100 | 1000 | 0,0212 |
CE10.020* | 241 | 247 | 226 | 232 | 154 | 100 | 1000 | 0,0218 |
* it is possible to make an opening in the bottom and mount a drain connector DN75 or DN110
SYTEC polymer concrete drainage wells with a galvanised steel strainer basket and cast iron COC grating
INDEX | LOAD CLASS | GRATING INSTALLATION METHOD | OUTFLOW | HEIGHT H Z [mm] | WIDTH D Z [mm] | WIDTH D W [mm] | LENGTH L [mm] | |
for CE10 channel | ||||||||
CE10.SB.Z.FK | F900 | Screw fixed | 2x110pcv (seal) or 160pcv (connector – made to order) | 550 | 154 | 100 | 500 | |
CE10.SB.S.FK | Snap fastened | 550 | 154 | 100 | 500 | |||
CE10.SB.U.FK | Double* | 550 | 154 | 100 | 500 |
* Double (snap fastened – screw fixed)
Accessories for CE channels
End caps for channels
INDEX | TYPE | INTENDED FOR TYPE HEIGHT H Z [mm] | INTENDED FOR CHANNELS OF INDEXES | WEIGHT [kg] |
SE/CE10.E20 | Full | 127, 187, 247 | CE10.001, CE10.005, CE10.010, CE10.015, CE10.020 | 1,0 |
SE/CE10.OP10 | Open with a connectorPEHD ф110 | 187 | CE10.010 | 1,0 |
SE/CE10.OP20 | Open with a connector PEHD ф110 | 247 | CE10.020 | 1,4 |
SE/CE10.OU10 | Open with a connector PCV ф110 | 187 | CE10.010 | 1,0 |
SE/CE10.OU20 | Open with a connector PCV ф110 | 247 | CE10.020 | 1,4 |
Gratings COC
INDEX | GRATING MATERIAL | GRATING TYPE | GRATING INSTALLATION METHOD | LOAD CLASS | HEIGHT [mm] | Water inlet surface area [cm2/piece] | |
for CE10 channels | |||||||
COC10.05.S.W | Cast iron | Slot | Snap fastened (spring) | F900 | 500 | 167 | |
COC10.05.Z.W | Cast iron | Slot | Screw fixed | F900 | 500 | 167 | |
COC10.05.U.W | Cast iron | Slot | Double (snap fastened - screw fixed) | F900 | 500 | 167 |
SYTEC drains with a protective edge
INDEX | HEIGHT H Z [mm] | HEIGHT H W [mm] | WIDTH D Z [mm] | WIDTH D W [mm] | LENGTH L [mm] |
Cast iron edging strips F900 | |||||
for CE10 channels | |||||
CE10.L00/H00 | 127 | 112 | 154 | 100 | 1000/500 |
CE10.L10/H10 | 187 | 172 | 154 | 100 | 1000/500 |
CE10.L20/H20 | 247 | 232 | 154 | 100 | 1000/500 |
SYTEC polymer concrete drainage wells with a galvanised steel strainer basket and cast iron COC grating
INDEX | LOAD CLASS | GRATING INSTALLATION METHOD | OUTFLOW | HEIGHT H Z [mm] | WIDTH D Z [mm] | WIDTH D W [mm] | LENGTH L [mm] | |
for CE10 channels | ||||||||
CE10.SB.Z.FK | F900 | Screw fixed | 2x110pcv (seal) or 160pcv (connector – made to order) | 550 | 154 | 100 | 500 | |
CE10.SB.S.FK | Snap fastened | 550 | 154 | 100 | 500 | |||
CE10.SB.U.FK | Double* | 550 | 154 | 100 | 500 |
*Double (snap fastened - screw fixed)
Accessories for CM channels
End caps for channels
FOR CHANNELS CE and SE FIT THE SAME PLUGS FULL AND PLUGS WITH NUTS.
INDEX | TYPE | INTENDED FOR TYPE HEIGHT H Z [mm] | INTENDED FOR CHANNELS OF INDEXES | WEIGTH [kg] | |
for SE/CE10 channels | |||||
SE/CE10.E20 | Full | 127, 187, 247 | CE10.L00/10/20, CE10.H00/10/20 | 1,0 | |
SE/CE10.OP00 | Open with a connector PEHD ф110 | 127 | CE10.L00, CE10.H00 | 0,6 | |
SE/CE10.OP10 | Open with a connector PEHD ф110 | 187 | CE10.L10, CE10.H10 | 1,0 | |
SE/CE10.OP20 | Open with a connector PEHD ф110 | 247 | CE10.L20, CE10.H20 | 1,4 | |
SE/CE10.OU00 | Open with a connector PCV ф110 | 127 | CE10.L00, CE10.H00 | 0,6 | |
SE/CE10.OU10 | Open with a connector PCV ф110 | 187 | CE10.L10, CE10.H10 | 1,0 | |
SE/CE10.OU20 | Open with a connector PCV ф110 | 247 | CE10.L20, CE10.H20 | 1,4 |
SYTEC cascade connectors
INDEX | WIDTH D Z [mm] | WEIGHT [kg] |
SE/CE10.SC | 130 | 1,3 |
Gratings COC
INDEX | GRATING MATERIAL | GRATING TYPE | GRATING INSTALLATION METHOD | LOAD CLASS | LENGTH [mm] | Water inlet surface area [cm2/piece] | |
for CE10 channels | |||||||
COC10.05.S.W | Cast iron | Slot | Snap fastened (spring) | F900 | 500 | 167 | |
COC10.05.Z.W | Cast iron | Slot | Screw fixed | F900 | 500 | 167 | |
COC10.05.U.W | Cast iron | Slot | Double (snap fastened - screw fixed) | F900 | 500 | 167 |
SYTEC drains with a protective edge
INDEX | HEIGHT H Z [mm] | HEIGHT H W [mm] | WIDTH D Z [mm] | WIDTH D W [mm] | LENGTH L [mm] |
Cast iron edging strips F900 | |||||
for CE15 channels | |||||
CE15.L00/H00 | 225 | 210 | 204 | 150 | 1000/500 |
CE15.L10/H10 | 275 | 260 | 204 | 150 | 1000/500 |
CE15.L20/H20 | 325 | 310 | 204 | 150 | 1000/500 |
SYTEC polymer concrete drainage wells with a galvanised steel strainer basket and cast iron COC grating
INDEX | LOAD CLASS | GRATING INSTALLATION METHOD | OUTFLOW | HEIGHT H Z [mm] | WIDTH D Z [mm] | WIDTH D W [mm] | LENGTH L [mm] | |
for CE15 channels | ||||||||
CE15.SB1.Z.FK | F900 | Screw fixed | It is possible to make an opening ф110 or ф160 or ф200 and mount a connector | 415 | 204 | 150 | 500 | |
CE15.SB1.S.FK | Snap fastened (spring) | 415 | 204 | 150 | 500 | |||
CE15.SB1.U.FK | Double* | 415 | 204 | 150 | 500 | |||
CE15.SB2.Z.FK | Screw fixed | 780 | 204 | 150 | 500 | |||
CE15.SB2.S.FK | Snap fastened (spring) | 780 | 204 | 150 | 500 | |||
CE15.SB2.U.FK | Double* | 780 | 204 | 150 | 500 | |||
CE15.SB3.Z.FK | Screw fixed | 1140 | 204 | 150 | 500 | |||
CE15.SB3.S.FK | Snap fastened (spring) | 1140 | 204 | 150 | 500 | |||
CE15.SB3.U.FK | Double* | 1140 | 204 | 150 | 500 | |||
SE/CE15.SB.P | Intermediate segment | 360 | 204 | 150 | 500 |
*Double (snap fastened - screw fixed)
Accessories for CE channels
End caps for channels
FOR CHANNELS CE and SE FIT THE SAME PLUGS FULL AND PLUGS WITH NUTS.
INDEX | TYPE | INTENDED FOR TYPE HEIGHT H Z [mm] | INTENDED FOR CHANNELS OF INDEXES | WEIGHT [kg] | |
for SE/CE15 channels | |||||
SE/CE15.E20 | Full | 225, 275, 325 | CE15.L00/10/20, CE15.H00/10/20 | 3,1 | |
SE/CE15.OP00 | Open with a connector PEHD ф160 | 225 | CE15.L00, CE15.H00 | 1,9 | |
SE/CE15.OP10 | Open with a connector PEHD ф160 | 275 | CE15.L10, CE15.H10 | 2,6 | |
SE/CE15.OP20 | Open with a connectorPEHD ф160 | 325 | CE15.L20, CE15.H20 | 3,2 | |
SE/CE15.OU00 | Open with a connector PCV ф160 | 225 | CE15.L00, CE15.H00 | 1,9 | |
SE/CE15.OU10 | Open with a connector PCV ф160 | 275 | CE15.L10, CE15.H10 | 2,6 | |
SE/CE15.OU20 | Open with a connector PCV ф160 | 325 | CE15.L20, CE15.H20 | 3,2 |
SYTEC cascade connectors
INDEX | WIDTH D Z [mm] | WEIGHT [kg] |
SE/CE15.SC | 190 | 1,5 |
Gratings COC
INDEX | GRATING MATERIAL | GRATING TYPE | GRATING INSTALLATION METHOD | LOAD CLASS | LENGTH [mm] | Water inlet surface area [cm2/piece] | |
for CE15 channels | |||||||
COC15.05.S.W | Cast iron | Slot | Snap fastened (spring) | F900 | 500 | 289 | |
COC15.05.Z.W | Cast iron | Slot | Screw fixed | F900 | 500 | 289 | |
COC15.05.U.W | Cast iron | Slot | Double (snap fastened - screw fixed) | F900 | 500 | 289 |
SYTEC drains with a protective edge
INDEX | HEIGHT H Z [mm] | HEIGHT H W [mm] | WIDTH D Z [mm] | WIDTH D W [mm] | LENGTH L [mm] |
Cast iron edging strips F900 | |||||
for CE20 channels | |||||
CE20.L00/H00 | 295 | 280 | 254 | 200 | 1000/500 |
CE20.L10/H10 | 345 | 330 | 254 | 200 | 1000/500 |
CE20.L20/H20 | 395 | 380 | 254 | 200 | 1000/500 |
SYTEC polymer concrete drainage wells with a galvanised steel strainer basket and cast iron COC grating
INDEX | LOAD CLASS | GRATING INSTALLATION METHOD | OUTFLOW | HEIGHT H Z [mm] | WIDTH D Z [mm] | WIDTH D W [mm] | LENGTH L [mm] | |
for CE20 channels | ||||||||
CE20.SB1.Z.FK | F900 | Screw fixed | It is possible to make an opening ф110 or ф160 or ф200 and mount a connector | 415 | 254 | 200 | 500 | |
CE20.SB1.S.FK | Snap fastened | 415 | 254 | 200 | 500 | |||
CE20.SB1.U.FK | Double* | 415 | 254 | 200 | 500 | |||
CE20.SB2.Z.FK | Screw fixed | 780 | 254 | 200 | 500 | |||
CE20.SB2.S.FK | Snap fastened | 780 | 254 | 200 | 500 | |||
CE20.SB2.U.FK | Double* | 780 | 254 | 200 | 500 | |||
CE20.SB3.Z.FK | Screw fixed | 1140 | 254 | 200 | 500 | |||
CE20.SB3.S.FK | Snap fastened | 1140 | 254 | 200 | 500 | |||
CE20.SB3.U.FK | Double* | 1140 | 254 | 200 | 500 | |||
SE/CE20.SB.P | Segment pośredni | 360 | 254 | 200 | 500 |
*Double (snap fastened - screw fixed)
Accessories for CE channels
End caps for channels
FOR CHANNELS CE and SE FIT THE SAME PLUGS FULL AND PLUGS WITH NUTS.
INDEX | TYPE | INTENDED FOR TYPE HEIGHT H Z [mm] | INTENDED FOR CHANNELS OF INDEXES | WEIGHT [kg] | |
for SE/CE20 channels | |||||
SE/CE20.E20 | Full | 295, 345, 395 | CE20.L00/10/20, CE20.H00/10/20 | 4,7 | |
SE/CE20.OP00 | Open with a connector PEHD ф160 | 295 | CE20.L00, CE20.H00 | 3,9 | |
SE/CE20.OP10 | Open with a connector PEHD ф160 | 345 | CE20.L10, CE20.H10 | 4,8 | |
SE/CE20.OP20 | Open with a connector PEHD ф160 | 395 | CE20.L20, CE20.H20 | 5,6 | |
SE/CE20.OU00 | Open with a connector PCV ф160 | 295 | CE20.L00, CE20.H00 | 3,9 | |
SE/CE20.OU10 | Open with a connector PCV ф160 | 345 | CE20.L10, CE20.H10 | 4,8 | |
SE/CE20.OU20 | Open with a connector PCV ф160 | 395 | CE20.L20, CE20.H20 | 5,6 |
SYTEC cascade connectors
INDEX | WIDTH D Z [mm] | WEIGHT [kg] |
SE/CE20.SC | 240 | 2,3 |
Gratings COC
INDEX | GRATING MATERIAL | GRATING TYPE | GRATING INSTALLATION METHOD | LOAD CLASS | LENGTH [mm] | Water inlet surface area [cm2/piece] | |
for CE20 channels | |||||||
COC20.05.S.W | Cast iron | Slot | Snap fastened (spring) | F900 | 500 | 512 | |
COC20.05.Z.W | Cast iron | Slot | Screw fixed | F900 | 500 | 503 | |
COC20.05.U.W | Cast iron | Slot | Double (snap fastened - screw fixed) | F900 | 500 | 503 |
SYTEC drains with a protective edge
INDEX | HEIGHT H Z [mm] | HEIGHT H W [mm] | WIDTH D Z [mm] | WIDTH D W [mm] | LENGTH L [mm] |
Cast iron edging strips F900 | |||||
for CE30 channels | |||||
CE30.L00/H00 | 415 | 390 | 354 | 300 | 1000/500 |
CE30.L10/H10 | 465 | 440 | 354 | 300 | 1000/500 |
CE30.L20/H20 | 515 | 490 | 354 | 300 | 1000/500 |
SYTEC polymer concrete drainage wells with a galvanised steel strainer basket and cast iron COC grating
INDEX | LOAD CLASS | GRATING INSTALLATION METHOD | OUTFLOW | HEIGHT H Z [mm] | WIDTH D Z [mm] | WIDTH D W [mm] | LENGTH L [mm] | |
for CE30 channels | ||||||||
CE30.SB.Z.FK | F900 | Screw fixed | 2x200pcv (uszczelka) | 835 | 354 | 300 | 500 | |
CE30.SB.S.FK | Snap fastened | 835 | 354 | 300 | 500 | |||
CE30.SB.U.FK | Double* | 835 | 354 | 300 | 500 | |||
SE/CE30.SB.P | Intermediate segment | 320 | 354 | 300 | 500 | |||
SE/CE30.P30 | Adapter for connecting channels SE/CE30.L/H00/10 to the drain pit |
* Double (snap fastened - screw fixed)
Accessories for CE channels
End caps for channels
FOR CHANNELS CE and SE FIT THE SAME PLUGS FULL AND PLUGS WITH NUTS.
INDEX | TYPE | INTENDED FOR TYPE HEIGHT H Z [mm] | INTENDED FOR CHANNELS OF INDEXES | WEIGHT kg] | |
for SE/CE30 channels | |||||
SE/CE30.E20 | Full | 415, 465, 515 | CE30.L00/10/20, CE30.H00/10/20 | 8,5 | |
SE/CE30.OP00 | Open with a connector PEHD ф200 | 415 | CE30.L00, CE30.H00 | 8,2 | |
SE/CE30.OP10 | Open with a connector PEHD ф200 | 465 | CE30.L10, CE30.H10 | 9,4 | |
SE/CE30.OP20 | Open with a connector PEHD ф200 | 515 | CE30.L20, CE30.H20 | 10,6 | |
SE/CE30.OU00 | Open with a connector PCV ф200 | 415 | CE30.L00, CE30.H00 | 8,2 | |
SE/CE30.OU10 | Open with a connectorPCV ф200 | 465 | CE30.L10, CE30.H10 | 9,4 | |
SE/CE30.OU20 | Open with a connector PCV ф200 | 515 | CE30.L20, CE30.H20 | 10,6 |
SYTEC cascade connectors
INDEX | WIDTH D Z [mm] | WEIGHT [kg] |
SE/CE30.SC | 340 | 4,0 |
Gratings COC
INDEX | GRATING MATERIAL | GRATING TYPE | GRATING INSTALLATION METHOD | LOAD CLASS | LENGTH [mm] | Water inlet surface area [cm2/piece] | |
for CE30 channels | |||||||
COC30.05.S.W | Cast iron | Slot | Snap fastened (spring) | F900 | 500 | 648 | |
COC30.05.Z.W | Cast iron | Slot | Screw fixed | F900 | 500 | 648 | |
COC30.05.U.W | Cast iron | Slot | Double (snap fastened - screw fixed) | F900 | 500 | 648 |
File name | File size | |
---|---|---|
Technical Data Sheet CE | 2807 KB | download |
Installation manual CE | 51 KB | download |