IMPORTANT: SE channels are „M” type channels according to PN-EN1433 and require an additional support in a form of a concrete apron. Channels should be installed according to SE/SSE LINEAR DRAINAGE INSTALLATION MANUAL
Functions of the system:
Collecting and disposing storm water from the surface of roads, streets and yards into a drain well and sewerage or storm drainage network, a combined sewer system or directly to a collector situated behind the drain well.
Application scope:
Type “M” units - groups 1-5 of application areas with load class A15-E600 according to PN-EN 1433, among others industrial areas of heavy traffic and high load etc.
Special area of application:
Collecting and disposing storm water from the surface of circulation routes for pedestrian and bicycle traffic, green areas e.g. parks, squares, domestic areas, including domestic garages, kerb zones, shoulders not burdened with traffic, car parks or parking bays for passenger cars, carriageways, shoulders and car parks for any type of road vehicles, areas subject to heavy loads caused by vehicular traffic e.g. ports and docks.
SYTEC drains with a protective edge
INDEX | HEIGHT H z [mm] | WIDTH D z [mm] | WIDTH D w [mm] | LENGTH L [mm] | ||||
Edging strips / load class | ||||||||
Steel galvanised | Steel, stainless | Cast iron | BEGINNING | END | ||||
A15 – C250 | D400- E600 | |||||||
SE10.001 | SSE10.001 | SE10.001U | 127 | 133 | 130 | 100 | 1000 | |
SE10.002 | SSE10.002 | SE10.002U | 133 | 139 | 130 | 100 | 1000 | |
SE10.003 | SSE10.003 | SE10.003U | 139 | 145 | 130 | 100 | 1000 | |
SE10.004 | SSE10.004 | SE10.004U | 145 | 151 | 130 | 100 | 1000 | |
SE10.005* | SSE10.005* | SE10.005U* | 151 | 157 | 130 | 100 | 1000 | |
SE10.006 | SSE10.006 | SE10.006U | 157 | 163 | 130 | 100 | 1000 | |
SE10.007 | SSE10.007 | SE10.007U | 163 | 169 | 130 | 100 | 1000 | |
SE10.008 | SSE10.008 | SE10.008U | 169 | 175 | 130 | 100 | 1000 | |
SE10.009 | SSE10.009 | SE10.009U | 175 | 181 | 130 | 100 | 1000 | |
SE10.010* | SSE10.010* | SE10.010U* | 181 | 187 | 130 | 100 | 1000 | |
SE10.011 | SSE10.011 | SE10.011U | 187 | 193 | 130 | 100 | 1000 | |
SE10.012 | SSE10.012 | SE10.012U | 193 | 199 | 130 | 100 | 1000 | |
SE10.013 | SSE10.013 | SE10.013U | 199 | 205 | 130 | 100 | 1000 | |
SE10.014 | SSE10.014 | SE10.014U | 205 | 211 | 130 | 100 | 1000 | |
SE10.015* | SSE10.015* | SE10.015U* | 211 | 217 | 130 | 100 | 1000 | |
SE10.016 | SSE10.016 | SE10.016U | 217 | 223 | 130 | 100 | 1000 | |
SE10.017 | SSE10.017 | SE10.017U | 223 | 229 | 130 | 100 | 1000 | |
SE10.018 | SSE10.018 | SE10.018U | 229 | 235 | 130 | 100 | 1000 | |
SE10.019 | SSE10.019 | SE10.019U | 235 | 241 | 130 | 100 | 1000 | |
SE10.020* | SSE10.020* | SE10.020U* | 241 | 247 | 130 | 100 | 1000 |
* it is possible to make a vertical outlet in the bottom - connector DN75 or DN110
SYTEC polymer concrete drainage wells with a galvanised steel strainer basket and cast iron COC grating
PRODUCT INDEX |
LOAD CLASS |
GRATING INSTALLATION METHOD |
OUTFLOW |
HEIGHT H Z [mm] |
WIDTH D Z [mm] |
WIDTH D W [mm] |
LENGTH L [mm] |
for SE10 channels |
|||||||
SE10.SB.Z.CK |
C250 |
Screw fixed |
2x110pcv (seal) and a possibility to make an opening and mount a connector ф160. |
550 |
130 |
100 |
500 |
SE10.SB.S.CK* |
Snap fastened |
550 |
130 |
100 |
500 |
||
SE10.SB.U.CK* |
Double** |
550 |
130 |
100 |
500 |
||
SE10.SB.Z.EK |
E600 |
Screw fixed |
550 |
130 |
100 |
500 |
|
SE10.SB.S.EK* |
Snap fastened |
550 |
130 |
100 |
500 |
||
SE10.SB.U.EK* |
Double** |
550 |
130 |
100 |
500 |
* Wells are available only with cast iron edging strips
** Double (snap fastened – screw fixed)
Note: In case of wells with steel strips, assembly can be only with screws.
Accessories for SE channels
End caps for channels
PRODUCT INDEX | TYPE | INTENDED FOR HEIGHT HZ [mm] | INTENDED FOR CHANNELS OF INDEXES | WEIGHT [kg] |
SE/CE10.E20 | Full | 127, 187, 247 | SE10.001, SE10.001U, SE10.005, SE10.005U, SE10.010, SE10.010U, SE10.015, SE10.015U, SE10.020, SE10.020U | 1,0 |
SE/CE10.OP10 | Open with a connector PEHD ф110 | 187 | SE10.010, SE10.010U | 1,0 |
SE/CE10.OP20 | Open with a connector PEHD ф110 | 247 | SE10.020, SE10.020U | 1,4 |
SE/CE10.OU10 | Open with a connector PCV ф110 | 187 | SE10.010, SE10.010U | 1,0 |
SE/CE10.OU20 | Open with a connector PCV ф110 | 247 | SE10.020, SE10.020U | 1,4 |
SSE10.E20 | Full | 127, 187, 247 | SSE10.001, SSE10.005, SSE10.010, SSE10.015, SSE10.020 | 1,0 |
SSE10.OP10 | Open with a connector PEHD ф110 | 187 | SSE10.010 | 1,0 |
SSE10.OP20 | Open with a connector PEHD ф110 | 247 | SSE10.020 | 1,4 |
SSE10.OU10 | Open with a connector PCV ф110 | 187 | SSE10.010 | 1,0 |
SSE10.OU20 | Open with a connector PCV ф110 | 247 | SSE10.020 | 1,4 |
Gratings COC
PRODUCT INDEX |
GRATING MATERIAL |
GRATING TYPE |
GRATING INSTALLATION METHOD |
LOAD CLASS |
LENGTH [MM] |
Water inlet surface area [cm2/pc] |
for SE10 channels |
||||||
COC10.01.W2 |
Cast iron |
Slot |
Screw fixed |
B125 |
500 |
163 |
COC10.02.Z.W |
Cast iron |
Slot |
Screw fixed |
C250 |
500 |
157 |
COC10.02.S.W1 |
Cast iron |
Slot |
Snap fastened (spring) |
500 |
161 |
|
COC10.02.U.W1 |
Cast iron |
Slot |
Double (snap fastened - screw fixed) |
500 |
157 |
|
COC10.04.Z.W |
Cast iron |
Slot |
Screw fixed |
E600 |
500 |
157 |
COC10.04.S.W1 |
Cast iron |
Slot |
Snap fastened (spring) |
500 |
161 |
|
COC10.04.U.W1 |
Cast iron |
Slot |
Double (snap fastened - screw fixed) |
500 |
157 |
1 only in channels with cast iron edging
2 only in channels with steel edging
SYTEC drains with a protective edge
PRODUCT INDEX |
HEIGHT H Z [mm] |
HEIGHT H W [mm] |
WIDTH D Z [mm] |
WIDTH D W [mm] |
LENGTH L [mm] |
|
Steel galvanised |
Steel, stainless |
|||||
for SE10 channels |
||||||
SE10.L00* |
SE10.L00U |
127 |
112 |
130 |
100 |
1000 |
SE10.H00* |
SE10.H00U |
127 |
112 |
130 |
100 |
500 |
SE10.L10* |
SE10.L10U |
187 |
172 |
130 |
100 |
1000 |
SE10.H10* |
SE10.H10U |
187 |
172 |
130 |
100 |
500 |
SE10.L20* |
SE10.L20U |
247 |
232 |
130 |
100 |
1000 |
SE10.H20* |
SE10.H20U |
247 |
232 |
130 |
100 |
500 |
* only in classes from A15 to C250
SYTEC polymer concrete drainage wells with a galvanised steel strainer basket and cast iron COC grating
PRODUCT INDEX |
LOAD CLASS |
GRATING INSTALLATION METHOD |
OUTFLOW |
HEIGHT H Z [mm] |
WIDTH D Z [mm] |
WIDTH D W [mm] |
LENGTH L [mm] |
for SE10 channels | |||||||
SE10.SB.Z.CK | C250 | Screw fixed | 2x110pcv (seal) and a possibility to make an opening and mount a connector ф160. | 550 | 130 | 100 | 500 |
SE10.SB.S.CK* | Snap fastened | 550 | 130 | 100 | 500 | ||
SE10.SB.U.CK* | Double** | 550 | 130 | 100 | 500 | ||
SE10.SB.Z.EK | E600 | Screw fixed | 550 | 130 | 100 | 500 | |
SE10.SB.S.EK* | Snap fastened | 550 | 130 | 100 | 500 | ||
SE10.SB.U.EK* | Double** | 550 | 130 | 100 | 500 |
* Wells are available only with cast iron edging strips
** Double (snap fastened – screw fixed)
Note: In case of wells with steel strips, assembly can be only with screws.
Accessories for SE channels
End caps for channels
PRODUCT INDEX | TYPE | INTENDED FOR HEIGHT HZ [mm] | INTENDED FOR CHANNELS OF INDEXES | WEIGHT [kg] |
for SE/CE10 channels | ||||
SE/CE10.E20 | Full | 127, 187, 247 | SE10.L00/10/20, SE10.H00/10/20, SE10.L00/10/20U, SE10.H00/10/20U | 1,0 |
SE/CE10.OP00 | Open with a connector PEHD ф110 | 127 | SE10.L00, SE10.H00, SE10.L00U, SE10.H00U | 0,6 |
SE/CE10.OP10 | Open with a connector PEHD ф110 | 187 | SE10.L10, SE10.H10, SE10.L10U, SE10.H10U | 1,0 |
SE/CE10.OP20 | Open with a connector PEHD ф110 | 247 | SE10.L20, SE10.H20, SE10.L20U, SE10.H20U | 1,4 |
SE/CE10.OU00 | Open with a connector PCV ф110 | 127 | SE10.L00, SE10.H00, SE10.L00U, SE10.H00U | 0,6 |
SE/CE10.OU10 | Open with a connector PCV ф110 | 187 | SE10.L10, SE10.H10, SE10.L10U, SE10.H10U | 1,0 |
SE/CE10.OU20 | Otwarta z króćcem PCV ф110 | 247 | SE10.L20, SE10.H20, SE10.L20U, SE10.H20U | 1,4 |
Łączniki kaskadowe SYTEC
INDEKS PRODUKTU | SZEROKOŚĆ D Z [mm] | MASA [kg] |
SE/CE10.SC | 130 | 1,3 |
Gratings COC
PRODUCT INDEX | GRATING MATERIAL | GRATING TYPE | GRATING INSTALLATION METHOD | LOAD CLASS | LENGTH [MM] | Water inlet surface area [cm2/pc] |
dla kanałów typu SE10 | ||||||
COC10.01.W2 | Cast iron | Slot | Screw fixed | B125 | 500 | 163 |
COC10.02.Z.W | Cast iron | Slot | Śrubowy | C250 | 500 | 157 |
COC10.02.S.W1 | Cast iron | Slot | Snap fastened (spring) | 500 | 161 | |
COC10.02.U.W1 | Cast iron | Slot | Double (snap fastened - screw fixed) | 500 | 157 | |
COC10.04.Z.W | Cast iron | Slot | Screw fixed | E600 | 500 | 157 |
COC10.04.S.W1 | Cast iron | Slot | Snap fastened (spring) | 500 | 161 | |
COC10.04.U.W1 | Cast iron | Slot | Double (snap fastened - screw fixed) | 500 | 157 |
1 only in channels with cast iron edging
2 only in channels with steel edging
SYTEC drains with a protective edge
INDEX |
HEIGHT H Z [mm] |
HEIGHT H W [mm] |
WIDTH D Z [mm] |
WIDTH D W [mm] |
LENGTH L [mm] |
|
Galvanized steel strips |
Universal iron strips |
|||||
for SE15 channels |
||||||
SE15.L00 |
SE15.L00U |
225 |
210 |
190 |
150 |
1000 |
SE15.H00 |
SE15.H00U |
225 |
210 |
190 |
150 |
500 |
SE15.L10 |
SE15.L10U |
275 |
260 |
190 |
150 |
1000 |
SE15.H10 |
SE15.H10U |
275 |
260 |
190 |
150 |
500 |
SE15.L20 |
SE15.L20U |
325 |
310 |
190 |
150 |
1000 |
SE15.H20 |
SE15.H20U |
325 |
310 |
190 |
150 |
500 |
SYTEC polymer concrete drainage wells with a galvanised steel strainer basket and cast iron COC grating
INDEX |
LOAD CLASS |
GRATING INSTALLATION METHOD |
OUTFLOW |
HEIGHT H Z [mm] |
WIDTH D Z [mm] |
WIDTH D W [mm] |
LENGTH L [mm] |
for SE15 channels |
|||||||
SE15.SB1.Z.CK |
C250 |
Screw fixed |
It is possible to make an opening ф110 or ф160 or ф200 and mount a connector |
415 |
204 |
150 |
500 |
SE15.SB1.S.CK* |
Snap fastened |
415 |
204 |
150 |
500 |
||
SE15.SB1.U.CK* |
Double** |
415 |
204 |
150 |
500 |
||
SE15.SB2.Z.CK |
Screw fixed |
780 |
204 |
150 |
500 |
||
SE15.SB2.S.CK* |
Snap fastened |
780 |
204 |
150 |
500 |
||
SE15.SB2.U.CK* |
Double** |
780 |
204 |
150 |
500 |
||
SE15.SB3.Z.CK |
Screw fixed |
1140 |
204 |
150 |
500 |
||
SE15.SB3.S.CK* |
Snap fastened |
1140 |
204 |
150 |
500 |
||
SE15.SB3.U.CK* |
Double** |
1140 |
204 |
150 |
500 |
||
SE15.SB1.Z.DK |
D400 |
Screw fixed |
It is possible to make an opening ф110 or ф160 or ф200 and mount a connector |
415 |
204 |
150 |
500 |
SE15.SB1.S.DK* |
Snap fastened |
415 |
204 |
150 |
500 |
||
SE15.SB1.U.DK* |
Double** |
415 |
204 |
150 |
500 |
||
SE15.SB2.Z.DK |
Screw fixed |
780 |
204 |
150 |
500 |
||
SE15.SB2.S.DK* |
Snap fastened |
780 |
204 |
150 |
500 |
||
SE15.SB2.U.DK* |
Double** |
780 |
204 |
150 |
500 |
||
SE15.SB3.Z.DK |
Screw fixed |
1140 |
204 |
150 |
500 |
||
SE15.SB3.S.DK* |
Snap fastened |
1140 |
204 |
150 |
500 |
||
SE15.SB3.U.DK* |
Double** |
1140 |
204 |
150 |
500 |
||
SE15.SB1.Z.EK |
E600 |
Screw fixed |
It is possible to make an opening ф110 or ф160 or ф200 and mount a connector |
415 |
204 |
150 |
500 |
SE15.SB1.S.EK* |
Snap fastened |
415 |
204 |
150 |
500 |
||
SE15.SB1.U.EK* |
Double** |
415 |
204 |
150 |
500 |
||
SE15.SB2.Z.EK |
Screw fixed |
780 |
204 |
150 |
500 |
||
SE15.SB2.S.EK* |
Snap fastened |
780 |
204 |
150 |
500 |
||
SE15.SB2.U.EK* |
Double** |
780 |
204 |
150 |
500 |
||
SE15.SB3.Z.EK |
Screw fixed |
1140 |
204 |
150 |
500 |
||
SE15.SB3.S.EK* |
Snap fastened |
1140 |
204 |
150 |
500 |
||
SE15.SB3.U.EK* |
Double** |
1140 |
204 |
150 |
500 |
||
SE/CE15.SB.P |
Intermediate segment |
360 |
204 |
150 |
500 |
* Wells are available only with cast iron edging strips
** Double (snap fastened – screw fixed)
Note: In case of wells with steel strips, assembly can be only with screws.
Accessories for SE channels
End caps for channels
INDEX |
TYPE |
INTENDED FOR HEIGHT HZ [mm] |
INTENDED FOR CHANNELS OF INDEXES |
WEIGHT [kg] |
for SE/CE15 channels |
||||
SE/CE15.E20 |
Full |
225, 275, 325 |
SE15.L00/10/20, SE15.H00/10/20, SE15.L00/10/20U, SE15.H00/10/20U |
3,1 |
SE/CE15.OP00 |
Open with a connector PEHD ф160 |
225 |
SE15.L00, SE15.H00, SE15.L00U, SE15.H00U |
1,9 |
SE/CE15.OP10 |
Open with a connector PEHD ф160 |
275 |
SE15.L10, SE15.H10, SE15.L10U, SE15.H10U |
2,6 |
SE/CE15.OP20 |
Open with a connector PEHD ф160 |
325 |
SE15.L20, SE15.H20, SE15.L20U, SE15.H20U |
3,2 |
SE/CE15.OU00 |
Open with a connector PCV ф160 |
225 |
SE15.L00, SE15.H00, SE15.L00U, SE15.H00U |
1,9 |
SE/CE15.OU10 |
Open with a connector PCV ф160 |
275 |
SE15.L10, SE15.H10, SE15.L10U, SE15.H10U |
2,6 |
SE/CE15.OU20 |
Open with a connector PCV ф160 |
325 |
SE15.L20, SE15.H20, SE15.L20U, SE15.H20U |
3,2 |
SYTEC cascade connectors
INDEX | WIDTH D Z [mm] | WEIGHT [kg] |
SE/CE15.SC | 190 | 1,5 |
Gratings COC
INDEX |
GRATING MATERIAL |
GRATING TYPE |
GRATING INSTALLATION METHOD |
LOAD CLASS |
LENGTH [MM] |
Water inlet surface area [cm2/pc] |
for SE15 channels |
||||||
COC15.02.Z.W |
Cast iron |
Slot |
Screw fixed |
C250 |
500 |
351 |
COC15.02.S.W1 |
Cast iron |
Slot |
Snap fastened (spring) |
500 |
351 |
|
COC15.02.U.W1 |
Cast iron |
Slot |
Double (snap fastened - screw fixed) |
500 |
351 |
|
COC15.03.Z.W |
Cast iron |
Slot |
Screw fixed |
D400 |
500 |
351 |
COC15.03.S.W1 |
Cast iron |
Slot |
Snap fastened (spring) |
500 |
351 |
|
COC15.03.U.W1 |
Cast iron |
Slot |
Double (snap fastened - screw fixed) |
500 |
351 |
|
COC15.04.Z.W |
Cast iron |
Slot |
Screw fixed |
E600 |
500 |
282 |
COC15.04.S.W1 |
Cast iron |
Slot |
Snap fastened (spring) |
500 |
282 |
|
COC15.04.U.W1 |
Cast iron |
Slot |
Double (snap fastened - screw fixed) |
500 |
282 |
1 only in channels with cast iron edging
SYTEC drains with a protective edge
INDEX |
HEIGHT H Z [mm] |
HEIGHT H W [mm] |
WIDTH D Z [mm] |
WIDTH D W [mm] |
LENGTH L [mm] |
|
Galvanized steel strips |
Universal iron strips |
|||||
for SE20 channels |
||||||
SE20.L00 |
SE20.L00U |
295 |
280 |
240 |
200 |
1000 |
SE20.H00 |
SE20.H00U |
295 |
280 |
240 |
200 |
500 |
SE20.L10 |
SE20.L10U |
345 |
330 |
240 |
200 |
1000 |
SE20.H10 |
SE20.H10U |
345 |
330 |
240 |
200 |
500 |
SE20.L20 |
SE20.L20U |
395 |
380 |
240 |
200 |
1000 |
SE20.H20 |
SE20.H20U |
395 |
380 |
240 |
200 |
500 |
SYTEC polymer concrete drainage wells with a galvanised steel strainer basket and cast iron COC grating
INDEX |
LOAD CLASS |
GRATING INSTALLATION METHOD |
OUTFLOW |
HEIGHT H Z [mm] |
WIDTH D Z [mm] |
WIDTH D W [mm] |
LENGTH L [mm] |
for SE20 channels |
|||||||
SE20.SB1.Z.CK |
C250 |
Screw fixed |
It is possible to make an opening ф110 or ф160 or ф200 and mount a connector |
415 |
254 |
200 |
500 |
SE20.SB1.S.CK* |
Snap fastened |
415 |
254 |
200 |
500 |
||
SE20.SB1.U.CK* |
Double** |
415 |
254 |
200 |
500 |
||
SE20.SB2.Z.CK |
Screw fixed |
780 |
254 |
200 |
500 |
||
SE20.SB2.S.CK* |
Snap fastened |
780 |
254 |
200 |
500 |
||
SE20.SB2.U.CK* |
Double** |
780 |
254 |
200 |
500 |
||
SE20.SB3.Z.CK |
Screw fixed |
1140 |
254 |
200 |
500 |
||
SE20.SB3.S.CK* |
Snap fastened |
1140 |
254 |
200 |
500 |
||
SE20.SB3.U.CK* |
Double** |
1140 |
254 |
200 |
500 |
||
SE20.SB1.Z.DK |
D400 |
Screw fixed |
It is possible to make an opening ф110 or ф160 or ф200 and mount a connector |
415 |
254 |
200 |
500 |
SE20.SB1.S.DK* |
Snap fastened |
415 |
254 |
200 |
500 |
||
SE20.SB1.U.DK* |
Double** |
415 |
254 |
200 |
500 |
||
SE20.SB2.Z.DK |
Screw fixed |
780 |
254 |
200 |
500 |
||
SE20.SB2.S.DK* |
Snap fastened |
780 |
254 |
200 |
500 |
||
SE20.SB2.U.DK* |
Double** |
780 |
254 |
200 |
500 |
||
SE20.SB3.Z.DK |
Screw fixed |
1140 |
254 |
200 |
500 |
||
SE20.SB3.S.DK* |
Snap fastened |
1140 |
254 |
200 |
500 |
||
SE20.SB3.U.DK* |
Double** |
1140 |
254 |
200 |
500 |
||
SE20.SB1.Z.EK |
E600 |
Screw fixed |
It is possible to make an opening ф110 or ф160 or ф200 and mount a connector |
415 |
254 |
200 |
500 |
SE20.SB1.S.EK* |
Snap fastened |
415 |
254 |
200 |
500 |
||
SE20.SB1.U.EK* |
Double** |
415 |
254 |
200 |
500 |
||
SE20.SB2.Z.EK |
Screw fixed |
780 |
254 |
200 |
500 |
||
SE20.SB2.S.EK* |
Snap fastened |
780 |
254 |
200 |
500 |
||
SE20.SB2.U.EK* |
Double** |
780 |
254 |
200 |
500 |
||
SE20.SB3.Z.EK |
Screw fixed |
1140 |
254 |
200 |
500 |
||
SE20.SB3.S.EK* |
Snap fastened |
1140 |
254 |
200 |
500 |
||
SE20.SB3.U.EK* |
Double** |
1140 |
254 |
200 |
500 |
||
SE/CE20.SB.P |
Intermediate segment |
360 |
254 |
200 |
500 |
* Wells are available only with cast iron edging strips
** Double (snap fastened – screw fixed)
Note: In case of wells with steel strips, assembly can be only with screws.
Accessories for SE channels
End caps for channels
INDEX |
TYPE |
INTENDED FOR HEIGHT HZ [mm] |
INTENDED FOR CHANNELS OF INDEXES |
WEIGHT [kg] |
for SE/CE20 channels |
||||
SE/CE20.E20 |
Full |
295, 345, 395 |
SE20.L00/10/20, SE20.H00/10/20, SE20.L00/10/20U, SE20.H00/10/20U |
4,7 |
SE/CE20.OP00 |
Open with a connector PEHD ф160 |
295 |
SE20.L00, SE20.H00, SE20.L00U, SE20.H00U |
3,9 |
SE/CE20.OP10 |
Open with a connector PEHD ф160 |
345 |
SE20.L10, SE20.H10, SE20.L10U, SE20.H10U |
4,8 |
SE/CE20.OP20 |
Open with a connector PEHD ф160 |
395 |
SE20.L20, SE20.H20, SE20.L20U, SE20.H20U |
5,6 |
SE/CE20.OU00 |
Open with a connector PCV ф160 |
295 |
SE20.L00, SE20.H00, SE20.L00U, SE20.H00U |
3,9 |
SE/CE20.OU10 |
Open with a connector PCV ф160 |
345 |
SE20.L10, SE20.H10, SE20.L10U, SE20.H10U |
4,8 |
SE/CE20.OU20 |
Open with a connector PCV ф160 |
395 |
SE20.L20, SE20.H20, SE20.L20U, SE20.H20U |
5,6 |
SYTEC cascade connector
INDEX |
WIDTH D Z [mm] |
WEIGHT [kg] |
SE/CE20.SC |
240 |
2,3 |
Gratings COC
INDEX |
GRATING MATERIAL |
GRATING TYPE |
GRATING INSTALLATION METHOD |
LOAD CLASS |
LENGTH [MM] |
Water inlet surface area [cm2/pc] |
for SE20 channels |
||||||
COC20.02.Z.W |
Cast iron |
Slot |
Screw fixed |
C250 |
500 |
537 |
COC20.02.S.W1 |
Cast iron |
Slot |
Snap fastened (spring) |
500 |
537 |
|
COC20.02.U.W1 |
Cast iron |
Slot |
Double (snap fastened - screw fixed) |
500 |
537 |
|
COC20.03.Z.W |
Cast iron |
Slot |
Screw fixed |
D400 |
500 |
537 |
COC20.03.S.W1 |
Cast iron |
Slot |
Snap fastened (spring) |
500 |
537 |
|
COC20.03.U.W1 |
Cast iron |
Slot |
Double (snap fastened - screw fixed) |
500 |
648 |
|
COC20.04.Z.W |
Cast iron |
Slot |
Screw fixed |
E600 |
500 |
534 |
COC20.04.S.W1 |
Cast iron |
Slot |
Snap fastened (spring) |
500 |
512 |
|
COC20.04.U.W1 |
Cast iron |
Slot |
Double (snap fastened - screw fixed) |
500 |
534 |
1 only in channels with cast iron edging
SYTEC drains with a protective edge
INDEX | HEIGHT H Z [mm] | HEIGHT H W [mm] | WIDTH D Z [mm] | WIDTH D W [mm] | LENGTH L [mm] | |
Galvanized steel strips | Universal iron strips | |||||
for SE30 channels | ||||||
SE30.L00 | SE30.L00U | 415 | 390 | 340 | 300 | 1000 |
SE30.H00 | SE30.H00U | 415 | 390 | 340 | 300 | 500 |
SE30.L10 | SE30.L10U | 465 | 440 | 340 | 300 | 1000 |
SE30.H10 | SE30.H10U | 465 | 440 | 340 | 300 | 500 |
SE30.L20 | SE30.L20U | 515 | 490 | 340 | 300 | 1000 |
SE30.H20 | SE30.H20U | 515 | 490 | 340 | 300 | 500 |
SYTEC polymer concrete drainage wells with a galvanised steel strainer basket and cast iron COC grating
INDEX | LOAD CLASS | GRATING INSTALLATION METHOD | OUTFLOW | HEIGHT H Z [mm] | WIDTH D Z [mm] | WIDTH D W [mm] | LENGTH L [mm] |
for SE30 channels | |||||||
SE30.SB.Z.DK | D400 | Screw fixed | 2x200pcv (seal) | 835 | 354 | 300 | 500 |
SE30.SB.S.DK* | Snap fastened | 835 | 354 | 300 | 500 | ||
SE30.SB.U.DK* | Double** | 835 | 354 | 300 | 500 | ||
SE30.SB.Z.EK | E600 | Screw fixed | 2x200pcv (seal) | 835 | 354 | 300 | 500 |
SE30.SB.S.EK* | Snap fastened | 835 | 354 | 300 | 500 | ||
SE30.SB.U.EK* | Double** | 835 | 354 | 300 | 500 | ||
SE/CE30.SB.P | Intermediate segment | 320 | 354 | 300 | 500 | ||
SE/CE30.P30 | Adapter for connecting SE / CE 30.L / H00 / 10 ducts to a drain pit |
* Wells are available only with cast iron edging strips
** Double (snap fastened – screw fixed)
Note: In case of wells with steel strips, assembly can be only with screws.
Accessories for SE channels
End caps for channels
INDEX |
TYPE |
INTENDED FOR HEIGHT HZ [mm] |
INTENDED FOR CHANNELS OF INDEXES |
WEIGHT [kg] |
dla kanałów typu SE/CE30 |
||||
SE/CE30.E20 |
Full |
415, 465, 515 |
SE30.L00/10/20, SE30.H00/10/20, SE30.L00/10/20U, SE30.H00/10/20U |
8,5 |
SE/CE30.OP00 |
Open with a connector PEHD ф200 |
415 |
SE30.L00, SE30.H00, SE30.L00U, SE30.H00U |
8,2 |
SE/CE30.OP10 |
Open with a connector PEHD ф200 |
465 |
SE30.L10, SE30.H10, SE30.L10U, SE30.H10U |
9,4 |
SE/CE30.OP20 |
Open with a connector PEHD ф200 |
515 |
SE30.L20, SE30.H20, SE30.L20U, SE30.H20U |
10,6 |
SE/CE30.OU00 |
Open with a connector PCV ф200 |
415 |
SE30.L00, SE30.H00, SE30.L00U, SE30.H00U |
8,2 |
SE/CE30.OU10 |
Open with a connector PCV ф200 |
465 |
SE30.L10, SE30.H10, SE30.L10U, SE30.H10U |
9,4 |
SE/CE30.OU20 |
Open with a connector PCV ф200 |
515 |
SE30.L20, SE30.H20, SE30.L20U, SE30.H20U |
10,6 |
Sytec connectors cascade
INDEX |
WIDTH D Z [mm] |
WEIGHT [kg] |
SE/CE30.SC |
340 |
4,0 |
Gratings COC
INDEX | GRATING MATERIAL | GRATING TYPE | GRATING INSTALLATION METHOD | LOAD CLASS | LENGTH [MM] | Water inlet surface area [cm2/pc] |
dla kanałów typu SE30 | ||||||
COC30.03.Z.W | Cast iron | Slot | Screw fixed | D400 | 500 | 648 |
COC30.03.S.W1 | Cast iron | Slot | Snap fastened (spring) | 500 | 648 | |
COC30.03.U.W1 | Cast iron | Slot | Double (snap fastened - screw fixed) | 500 | 648 | |
COC30.04.Z.W | Cast iron | Slot | Screw fixed | E600 | 500 | 648 |
COC30.04.S.W1 | Cast iron | Slot | Snap fastened (spring) | 500 | 648 | |
COC30.04.U.W1 | Cast iron | Slot | Double (snap fastened - screw fixed) | 500 | 648 |
File name | File size | |
---|---|---|
Technical Data Sheet SE | 2978 KB | download |